UT586+ Digital RCD (ELCB) Tester «UNI-T»

Specification
Rate trigger current Fault trigger time Accuracy
(current)
Accuracy
(time)
RCD test function X1/2 10/20/30/100/300/500mA/1000mA 0~2000mS @  0°/180°  -10%~0%” ±0.6%rdg±4dgt
X1 10/20/30/100/300mA 0~2000mS @  0°/180° 0%~+10% ±0.6%rdg±4dgt
500mA/1000mA 0~200mS @  0°/180° 0%~+10% ±0.6%rdg±4dgt
X2 10/20/30/100/200/300/500mA 0~200mS @  0°/180° 0%~+10% ±0.6%rdg±4dgt
X5 10/20/30/100/200mA 0~200mS @  0°/180° 0%~+10% ±0.6%rdg±4dgt
AUTO  10/20/30/100/300/500mA/1000mA 300ms @ 15 0°/180° -10%~+10% ±0.6%rdg±4dgt
Manual  10/20/30/100/300/500mA/1000mA 300ms @ 0°/180° -10%~+10% ±0.6%rdg±4dgt
Working voltage  50/60Hz 100V~440V
(Note: If > 450V, it will issue an alarm and stop the RCD test)
-15%~+10%
Voltage test Voltage range 30~480V (Resolution: 1V) 45~65Hz ±3%rdg±3dgt
Voltage test L-PE yes, display the L-PE input voltage;
range: 30V~480V; No input and low voltage: “0V”;
if less than 30V: <30V; if  more than 4800v: >480V
Frequency yes, display the L-PE input frequency;
when it is “volts”, press “VOLT/FREQ” key to switch “Voltage/Frequency”
Wiring check If there is no wiring, an abnormal power supply, or no electricity flowing, the LCD will display “L-PE” and flash.
Phase angle selection You can choose to initiate the test from the positive (0°) or the negative (180°) half-cycle. Press the “0°/180°” button to toggle phase.
Lock test  With the power disconnected, press and hold the “0°/180°” button to activate the lock test function. Simply connect the test leads correctly to the test points, and the test will run automatically.
AUTO RAMP test You can test the trip action current and action time simultaneously.
RCD test exceeds limit prompt  When the trip action time exceeds the maximum test duration and trips.
Over-temperature detection  If the internal components of the device become too hot, the LCD will display an over-temperature symbol, and the device will automatically disable RCD testing.
Backlight Yes, can be turn on/off
Low battery indication yes
Auto powwer off After 5 minutes of no operation, it will automatically shut down.
Working environment 0℃~40℃
Storage environment  -20℃~60℃
Power 8 * 1.5V AA
Polution level 2
Safety rating IEC61010-031; IEC61557-1,6; CAT III 600V